Fluid Mechanics Lab

Our range of products include bernoulli's theorem apparatus, discharge through notches, impact of jet on vanes, losses due to friction in pipelines, losses due to pipe fittings, sudden enlargement & contraction and discharge through orificemeter.
Get CALLBACK

Bernoulli's Theorem Apparatus

Bernoulli's Theorem Apparatus
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-101
Sump Tank Capacity70 Ltrs.
Test SectionConvergent and Divergent section, Material Acrylic.
Piezometer TubesMaterial P.U. Tubes (7 Nos.)
Water Circulation1/2 HP Pump, Crompton/Standard make.
Flow MeasurementUsing Measuring Tank with Piezometer, Capacity 25 Ltrs.
Inlet Tank Capacity20 Ltrs. with fixed overflow arrangement.
Stop WatchElectronic

The present set-up is designed and fabricated todemonstrate the Bernoulli's theorem. It consists of a testsection having convergent and divergent section wherepressure tapings are provided at different locations tomeasure the pressure head, which is displayed onmanometer board.Centrifugal pump is used to re-circulate the water fromsump tank to the inlet tank and test section and is returnback to the sump tank. Flow diverter is provided to divertthe flow either to measuring tank or sump tank. Constanthead condition is maintained in the inlet tank.Experiments can be conducted on different flow ratesand measured with the help of measuring tank withpiezometer and stopwatch.
Yes! I am Interested
Get CALLBACK

Discharge Through Notches

Discharge Through Notches
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-103
Channel Test SectionSize 600 x 250 x 180 mm
NotchesMaterial Brass 1 No. each of Rectangular Notch, 45 degree V Notch, 60 degree V Notch
Pointer GaugeWith Vernier scale.
Water Circulation1/2 HP Pump Crompton/Standard make.
Flow MeasurementUsing Measuring Tank with Piezometer, Capacity 25 Ltrs.
Sump TankCapacity 50 Ltrs.

The present setup is designed to study the discharge overnotches. It consists of a flow channel of sufficient lengthand width fitted with calming section and flowsmoothening plates to achieve undisturbed flow. Set ofthree notches are provided which can be attached ordetached easily at the end of flow channel without needof extra tool. A pointer gauge with Vernier scale is fittedto measure the height of fluid in flow channel.Centrifugal pump is used to re-circulate the water fromsump tank to the Flow channel and test section and isreturn back to the sump tank. Flow diverter is provided todivert the flow either to measuring tank or sump tank.Experiments can be conducted on different flow ratesand measured with the help of measuring tank withpiezometer and stopwatch.
Yes! I am Interested
Get CALLBACK

Impact of Jet on Vanes

Impact of Jet on Vanes
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-104
TargetFlat Plate and Hemispherical Cup,1 No. each
NozzleMaterial Brass
Jet EnclosureMade of Acrylic
Counter weightsOne set of dead weights
Water CirculationFHP Pump,Standard make
Flow MeasurementUsing Measuring Tank with piezometer,Capacity 25 Ltrs.

The present setup is designed to study the impact of jeton stationary vanes. It consists of test section fitted witha nozzle at the bottom through which water is fed anddischarged vertically to strike a target carried on a stem,which extends through the cover. A weight carrier ismounted on the upper end of the stem and dead weightof the moving parts is counter balanced by a compressionspring. The vertical force exerted on the target plate ismeasured for applied weights. Two targets are providedwith the setup, which can be attached /detached easilywithout need of any extra tool.Centrifugal pump is used to re-circulate the water fromsump tank to the test section and is return back to thesump tank. Flow diverter is provided to divert the floweither to measuring tank or sump tank. Experiments canbe conducted on different flow rates and measured withthe help of measuring tank with piezometer andstopwatch.
Yes! I am Interested
Get CALLBACK

Losses Due to Friction in Pipelines

Losses Due to Friction in Pipelines
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-105
Pipe Test SectionDia 1/2 inch,Pr. Taping Length 1m,Dia 3/4 inch,Pr. Taping Length 1.25m
Pipe Test Section MaterialG.I.
Water Circulation1/2 HP Pump,Crompton/Standard make.
Flow MeasurementUsing Measuring Tank with Piezometer,Capacity 25 Ltr
Sump Tank Capacity50 ltrs.
Stop WatchElectronic.

The present set-up is designed to study the frictionallosses in pipe line when fluid travels through them. Itconsists of two pipes of different diameters connected inparallel and fitted with control valves to operate one pipeat a time for experiment. Pressure tapings are providedon each pipeline to measure the pressure differenceusing pressurized differential pressure manometer.Centrifugal pump is used to re-circulate the water fromsump tank to the pipeline and is return back to the sumptank. Flow diverter is provided to divert the flow either tomeasuring tank or sump tank. Experiments can beconducted on different flow rates and measured with thehelp of measuring tank with piezometer and stopwatch.
Yes! I am Interested
Get CALLBACK

Losses Due to Pipe Fittings, Sudden Enlargement & Contraction

Losses Due to Pipe Fittings, Sudden Enlargement & Contraction
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-106
Sudden EnlargementFrom 15mm to 25mm
Sudden ContractionFrom 25mm to 15mm.
Bend1/2 inch
Elbow1/2 inch
Ball Valve1/2 inch
Gate Valve1/2 inch
Water Circulation1/2 HP Pump,Crompton/Standard make

The present set-up is designed to study the pressurelosses due to pipe fittings installed in pipe lines. It consistsof a bend, elbow, a sudden expansion & contraction, ballvalve and gate valve. Pressure tapings are provided atinlet and outlet of these fittings to measure the pressuredifference using pressurized differential pressuremanometer.Centrifugal pump is used to re-circulate the water fromsump tank to the pipeline and is return back to the sumptank. Flow diverter is provided to divert the flow either tomeasuring tank or sump tank. Experiments can beconducted on different flow rates and measured with thehelp of measuring tank with piezometer and stopwatch.
Yes! I am Interested
Get CALLBACK

Discharge Through Orificemeter

Discharge Through Orificemeter
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-107
Orifice meterBody Material Acrylic, compatible to 1 inch Dia. Pipe.
Orifice Platemade of Stainless Steel
Water Circulation1/2 HP Pump, Crompton/Standard make.
Flow MeasurementUsing Measuring Tank with piezometer Capacity 25 Ltrs.
Sump Tank Capacity50 Ltrs.
Stop WatchElectronic

The present set-up is designed to study an orifice meterand to calculate fluid discharge through it. By determiningthe co-efficient of discharge of this orifice meter it can beused as a flow meter and can be installed in a fluid line.The apparatus consists of a pipe line with a transparentacrylic section in which a stainless steel orifice is installed.The pressure tapings from the Orifice meter is taken topressurized differential pressure manometer to measurepressure difference. Present set-up is self-containedwater re-circulating unit, provided with a sump tank,centrifugal pump etc. Water is pumped by means ofcentrifugal pump and passing through the test section, itreturns back to the sump which make the system recirculatingtype. Flow of water is diverted either tomeasuring tank or sump tank with the means of a flowdiverter, when needed. Flow control valve and by-passvalve are fitted in water line to conduct the experimenton different flow rates. Flow rate of water is measuredwith the help of measuring tank with piezometer andstopwatch. The supplied set-up is complete in all respect.Only water supply and electricity supply is to be providedby the end user for running the set-up.
Yes! I am Interested
Get CALLBACK

Discharge Through Venturimeter

Discharge Through Venturimeter
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-109
Venturi meterBody Material Acrylic, compatible to 1 inch Dia. Pipe
Water Circulation1/2 HP Pump, Crompton/Standard make.
Flow MeasurementUsing Measuring Tank with piezometer Capacity 25 Ltrs.
Sump Tank Capacity50 Ltrs.
Stop WatchElectronic
Pressure measurementBy Pressurized differential pressure manometer

The present set-up is designed to study an venturi meterand to calculate fluid discharge through it. By determiningthe co-efficient of discharge of this venturi meter it canbe used as a flow meter and can be installed in a fluidline. The apparatus consists of a pipe line in which atransparent venturi meter is installed. The pressuretapings from the venturi meter is taken to pressurizeddifferential pressure manometer to measure pressuredifference. Present set-up is self-contained water recirculatingunit, provided with a sump tank, centrifugalpump etc. Water is pumped by means of centrifugalpump and passing through the test section, it returnsback to the sump which make the system re-circulatingtype. Flow of water is diverted either to measuring tankor sump tank with the means of a flow diverter, whenneeded. Flow control valve and by-pass valve are fitted inwater line to conduct the experiment on different flowrates. Flow rate of water is measured with the help ofmeasuring tank with piezometer and stopwatch. Thesupplied set-up is complete in all respect. Only watersupply and electricity supply is to be provided by the enduser for running the set-up.
Yes! I am Interested
Get CALLBACK

Discharge Through Venturimeter & Orificemeter

Discharge Through Venturimeter & Orificemeter
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-110
Venturi meterBody Material Acrylic, compatible to 1 inch Dia. Pipe.
Orifice meterBody Material Acrylic, compatible to 1 inch Dia. Pipe.
Water Circulation1/2 HP Pump, Crompton/Standard make.
Flow MeasurementUsing Measuring Tank with piezometer Capacity 25 Ltrs
Sump Tank Capacity50 Ltrs.
Stop WatchElectronic

The present set-up is designed to study two types ofdifferential pressure based flow measuring devices. Oneis an orifice meter and other is Venturi meter. The set-upalso facilitates the end user to calculate fluid dischargethrough it. By determining the co-efficient of discharge ofthese flow meter these can be used as a direct flow meterand can be installed in a fluid line. The apparatus consistsof two pipe line emerging out from a common manifold.Both pipe line has been installed with a test section. Onehas venturi meter and other one has an orifice meter. Avalve arrangement is given to operate any one selectedtest section at time. Pressure taping from these flowmeters are taken out to pressurized differential pressuremanometer. Present set-up is self-contained water recirculatingunit, provided with a sump tank, centrifugalpump etc. Water is pumped by means of centrifugalpump and passing through the test sections, it returnsback to the sump which make the system re-circulatingtype. Flow of water is diverted either to measuring tankor sump tank with the means of a flow diverter, whenneeded. Flow control valve and by-pass valve are fitted inwater line to conduct the experiment on different flowrates. Flow rate of water is measured with the help ofmeasuring tank with piezometer and stopwatch. Thesupplied set-up is complete in all respect. Only watersupply and electricity supply is to be provided by the enduser for running the set-up.
Yes! I am Interested
Get CALLBACK

Discharge Through Venturimeter, Orificemeter & Rotameter

Discharge Through Venturimeter, Orificemeter & Rotameter
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-111
Venturi meterBody Material Acrylic,compatible to 1 inch Dia. Pipe.
Orifice meterBody Material Acrylic,compatible to 1 inch Dia. Pipe.
Orifice PlateMade of Stainless Steel
RotameterGlass Tube Rotameter.
Water Circulation1/2 HP Pump,Crompton/Standard Make.
Flow MeasurementUsing Measuring Tank with piezometer Capacity 25 Ltrs.
Sump Tank Capacity50 Ltrs.

The present set-up is designed to study three type of flowmeasuring devices. These are orifice meter, Venturimeter and rotameter. The set-up also facilitates the enduser to calculate fluid discharge through these devices. Bydetermining the co-efficient of discharge of venturi meterand orifice meter, these devices can be used as a directflow meter and can be installed in a fluid line. Rotameteris provided with a pre-calibrated scale. By passing aknown flow of fluid through the rotameter andcomparing this to provided scale reading, end user can recalibratethe rotameter.The apparatus consists of three pipe lines emerging outfrom a common manifold. All three pipe line has beeninstalled with a test section. One has venturi meter,second has an orifice meter and third one is having arotameter. The Venturi meter, Orifice meter andRotameter are connected in parallel and any one of themcan be put in operation by operating valves provided atthe downstream. Pressure taping from venturi meter andorifice meter are taken out to pressurized differentialpressure manometer.Present set-up is self-contained water re-circulating unit,provided with a sump tank, centrifugal pump etc. Wateris pumped by means of centrifugal pump and passingthrough the test sections, it returns back to the sumpwhich make the system re-circulating type. Flow of wateris diverted either to measuring tank or sump tank withthe means of a flow diverter, when needed. Flow controlvalve and by-pass valve are fitted in water line to conductthe experiment on different flow rates. Flow rate of wateris measured with the help of measuring tank withpiezometer and stopwatch. The supplied set-up iscomplete in all respect. Only water supply and electricitysupply is to be provided by the end user for running theset-up.
Yes! I am Interested
Get CALLBACK

Nozzle Meter Test Rig

Nozzle Meter Test Rig
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-112
Nozzle meterTest section made of Clear Acrylic. Compatible to 1 inch dia pipe.
Water Circulation1/2 HP Pump, Crompton/Standard make
Flow MeasurementUsing Measuring Tank with piezometer Capacity 25 Ltrs.
Sump Tank Capacity50 Ltrs.
Stop WatchElectronic
Pressure measurementBy Pressurized differential pressure manometer

The present set-up is designed to study a nozzle meterand to calculate fluid discharge through it. By determiningthe co-efficient of discharge of this nozzle meter it can beused as a flow meter and can be installed in a fluid line.The apparatus consists of a pipe line in which atransparent nozzle meter is installed. The pressuretapings from the nozzle meter is taken to pressurizeddifferential pressure manometer to measure pressuredifference.Present set-up is self-contained water re-circulating unit,provided with a sump tank, centrifugal pump etc. Wateris pumped by means of centrifugal pump and passingthrough the test section, it returns back to the sumpwhich make the system re-circulating type. Flow of wateris diverted either to measuring tank or sump tank withthe means of a flow diverter, when needed. Flow controlvalve and by-pass valve are fitted in water line to conductthe experiment on different flow rates. Flow rate of wateris measured with the help of measuring tank withpiezometer and stopwatch. The supplied set-up iscomplete in all respect. Only water supply and electricitysupply is to be provided by the end user for running theset-up.
Yes! I am Interested
Get CALLBACK

Reynold's Apparatus

Reynold's Apparatus
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-113
TubeMaterial Borosilicate Glass ID 14 mm approx., Length 600 mm
Dye vesselMaterial Stainless Steel, Capacity 1 Ltrs. (approx.)
Capillary TubeMaterial Stainless Steel.
Constant Head Water TankCapacity 40 Ltrs.
Water CirculationFHP Pump.
Measuring CylinderCapacity 1000 ml.

The apparatus consists of a glass tube with one endhaving bell mouth entrance. This glass tube with bellmouth entrance is connected to a constant head watertank. At the other end of this glass tube a valve isprovided to vary the flow rate of water. The tank is ofsufficient capacity to store water. A capillary tube isintroduced centrally in the bell mouth for feeding dyefrom a small container placed at the top of tank,connected through polythene tubing. By varying the rateof flow, the Reynold's number is changed. This alsochanges the type of flow. Visual observation of dye(Thread) will indicate the type of flow, which can beconfirmed from the Reynold's number computed. Presentset-up is self-contained water re-circulating unit, providedwith a sump tank, inlet tank, centrifugal pump etc. Wateris pumped by means of centrifugal pump and passingthrough the inlet tank & test section, it returns back tothe sump which make the system re-circulating type.Flow control valve and by-pass valve are fitted in waterline to conduct the experiment on different flow rates.Flow rate of water is measured with the help ofmeasuring cylinder and stopwatch. The supplied set-up iscomplete in all respect. Only water supply, electricitysupply and dye is to be provided by the end user forrunning the set-up.
Yes! I am Interested
Get CALLBACK

Pitot Tube Setup

Pitot Tube Setup
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-114
Pitot TubeMaterial Copper of compatible size fitted with venire scale
Test SectionMaterial Clear Acrylic,compatible to 1 inch Dia. Pipe
Water Circulation1/2 HP Pump,Crompton/Standard make.
Flow MeasurementUsing Measuring Tank with Piezometer (Capacity 25 Ltrs.)
Sump Tank Capacity50 Ltrs.
Stop WatchElectronic

A Pitot Tube is used to measure the local velocity at agiven point in the flow stream. A pitot tube of standarddesign made of copper is supplied and is fixed belowvenire scale. The venire scale is capable to measure theposition of Pitot Tube in transparent section. The pipehas a flow control valve to regulate the flow. Andifferential pressure manometer is provided to determinethe velocity head.Present set-up is self-contained water re-circulating unit,provided with a sump tank, centrifugal pump etc. Wateris pumped by means of centrifugal pump and passingthrough the test section, it returns back to the sumpwhich make the system re-circulating type. Flow of wateris diverted either to measuring tank or sump tank withthe means of a flow diverter, when needed. Flow controlvalve and by-pass valve are fitted in water line to conductthe experiment on different flow rates. Flow rate of wateris measured with the help of measuring tank withpiezometer and stopwatch. The supplied set-up iscomplete in all respect. Only water supply and electricitysupply is to be provided by the end user for running theset-up.
Yes! I am Interested
Get CALLBACK

Cavitation Apparatus

Cavitation Apparatus
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-115
Test SectionMaterial Acrylic
Pressure Gauge0-4 kg/cm2
Vacuum Gauge0-760 mmHg
Water CirculationBy Pump, Crompton/Standard make.
Flow MeasurementUsing Measuring Tank, Capacity 40 liters
Sump Tank Capacity60 Ltrs.
Stop WatchElectronic

The apparatus has been designed to demonstrate thephenomenon of cavitation. The present set-up consists ofa test section made of Acrylic having conversion anddiversion section. Pressure tapings at appropriateposition are provided. This test section is having onecontrol valve at upstream side to regulate the water flowrate. Two pressure gauges are connected to these tapingwhich give the pressure readout at the time of flowpassing through this test section.Present set-up is self-contained water re-circulating unit,provided with a sump tank, centrifugal pump etc. Wateris pumped by means of centrifugal pump and passingthrough the test section, it returns back to the sumpwhich make the system re-circulating type. Flow of wateris diverted either to measuring tank or sump tank withthe means of a flow diverter, when needed. Flow controlvalve and by-pass valve are fitted in water line to conductthe experiment on different flow rates. Flow rate of wateris measured with the help of measuring tank withpiezometer and stopwatch. The supplied set-up iscomplete in all respect. Only water supply and electricitysupply is to be provided by the end user for running theset-up.
Yes! I am Interested
Get CALLBACK

Laminar Flow Table

Laminar Flow Table
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-116
Flow Table Length750 mm (approx.)
Flow Table Width500 mm (approx)
Flow Table MaterialStainless Steel
Transparent SheetMaterial Glass/Acrylic
Water CirculationFHP Pump
Sump TankMaterial- Stainless Steel, Capacity 90 Ltrs

The present set-up is designed to visualize the ideal flowaround immersed body. It consists of a flow table inwhich flow of water is circulated in between twotransparent sheets with a small gap between them.Water is supplied to the table and a coloured dye isinjected in the inlet of water flow at different location.Flow is made laminar by operating inlet control valve forwater and it is visualized due to transparent sheet andcoloured dye. A small capacity dye tank is provided whichprovides flow of dye to be injected in fluid inlet stream.Any obstacle can be placed between the sheets andchange in flow pattern can be visualized. Obstacles ofdifferent types will be supplied with the apparatus.Present set-up is self-contained water re-circulating unit,provided with a sump tank, inlet calming section,centrifugal pump etc. Water is pumped by means ofcentrifugal pump and passing through the inlet tank &test section, it returns back to the sump which make thesystem re-circulating type. Flow control valve and by-passvalve are fitted in water line to conduct the experimenton different flow rates. The supplied set-up is complete inall respect. Only water supply, electricity supply and dyeis to be provided by the end user for running the set-up.
Yes! I am Interested
Get CALLBACK

Metacentric Height Apparatus

Metacentric Height Apparatus
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-117
PontoonMaterial Acrylic, provided with Horizontal Guide Bar for sliding weight Removable Strips Pointer wi
Water TankSize 550 x 500 x 400 mm (approx.)
Transparent WindowMade of Glass/Perspex
Tankmade of stainless steel
Pendulum and graduated scalefor accurate measurement of Tilt angle.

The present set-up is designed to study the metacentricheight of a ship model. It consists of a Rectangular tankwith one side transparent and a pontoon is allowed tofloat in this tank. The pontoon position on the water isvisualized through the transparent side. Suppliedremovable steel strips are placed in the ship model forthe purpose of changing the weight of the model.Displacement of weight is measured with the help of ascale. The angle of tilt can be measured by means of apendulum and a cross bar with movable hanger is fixedon the model to tilt the ship. A set of weights is suppliedwith the apparatus.
Yes! I am Interested
Get CALLBACK

Forced Vortex Apparatus

Forced Vortex Apparatus
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-120
CylinderMOC Acrylic.
Cylinder Dia200 mm (approx)
Cylinder Height200 mm (approx)
MotorVariable Speed DC Motor of Compatible capacity
ProbeMOC Stainless Steel
Cross SlideWith scale reading in cm

The present experimental set-up consist of a circulartransparent cylindrical tank, fixed on a stainless steelplate. This plate is rotated with the help of a variablespeed motor so that the cylinder rotates about its verticalaxis. The motor is supplied with speed control facility androtation of the transparent tank is displayed on a DigitalRPM Indicator.Water is filled in this tank up to certain level. When thiswater filled transparent tank rotates, a forced vortex isformed. An upper probe can be transversed horizontally& vertically across full diameter of the transparent tankso that water surface profile can be measure. Both axescontain graduations so that exact position of the probe isknown.The experimental procedure involves measurement ofthe resulting free surface that represents the variation ofthe sum of the pressure head and datum head. Anarrangement is provided to drain the vessel.
Yes! I am Interested
Get CALLBACK

Free Vortex Apparatus

Free Vortex Apparatus
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-121
CylinderMOC Acrylic.
Cylinder Dia200 mm (approx)
Cylinder Height200 mm (approx)
Flow MeasurementUsing Rotameter.
Orifices3 different openings
ProbeMOC Stainless Steel

The experimental set up consist of a circular transparentcylindrical tank fabricated with stainless steel at bottom.Near the bottom of the tank, four circumferential jets areplaced along the circumference of the cylinder. Thesecircumferential jets, near its bottom, helps in theformation of free vortex. It is assumed that the torqueexerted by these jets is negligible. Three differentinterchangeable openings are provided which can easilybe fixed at the bottom.A pointer can be transversed horizontally & verticallyacross full diameter of the vessel so that water surfaceprofile can be measure. Both axes contain graduations sothat exact position of the pointer is known.The experimental procedure involves measurement ofthe resulting free surface that represents the variation ofthe sum of the pressure head and datum head. Anarrangement is provided to drain the vessel.
Yes! I am Interested
Get CALLBACK

Free & Forced Vortex Apparatus

Free & Forced Vortex Apparatus
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-122
Cylinder made ofAcrylic
Cylinder Dia200 mm
Cylinder Height200 mm one each for Free Vortex and Forced Vortex.
MotorVariable Speed DC Motor of Compatible capacity.
ProbeMOC Stainless Steel
Cross SlideWith scale reading in cm.
Pump1/2 HP, Crompton/Standard make

The free vortex experimental set up consist of a circulartransparent cylindrical tank fabricated with stainless steelat bottom. Near the bottom of the tank, fourcircumferential jets are placed along the circumference ofthe cylinder. These circumferential jets, near its bottom,helps in the formation of free vortex. It is assumed thatthe torque exerted by these jets is negligible. Threedifferent interchangeable openings are provided whichcan easily be fixed at the bottom. A pointer can betransverse horizontally & vertically across full diameter ofthe vessel so that water surface profile can be measure.Both axes contain graduations so that exact position ofthe pointer is known. The experimental procedureinvolves measurement of the resulting free surface thatrepresents the variation of the sum of the pressure headand datum head. An arrangement is provided to drain thevessel.The forced experimental set-up consist of a circulartransparent cylindrical tank, fixed on a stainless steelplate. This plate is rotated with the help of a variablespeed motor so that the cylinder rotates about its verticalaxis. The motor is supplied with speed control facility androtation of the transparent tank is displayed on a DigitalRPM Indicator. Water is filled in this tank up to certainlevel. When this water filled transparent tank rotates, aforced vortex is formed. An upper probe can betransverse horizontally & vertically across full diameter ofthe transparent tank so that water surface profile can bemeasure. Both axes contain graduations so that exactposition of the probe is known. The experimentalprocedure involves measurement of the resulting freesurface that represents the variation of the sum of thepressure head and datum head. An arrangement isprovided to drain the vessel.
Yes! I am Interested
Get CALLBACK

Darcy's Law Apparatus

Darcy's Law Apparatus
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-123
Test SectionMaterial Stainless Steel Dia. 120 mm, Height 500 mm.
Water Circulation1/2 HP Pump, Crompton/Standard make
Flow MeasurementUsing Measuring Tank, Capacity 25 Ltrs. (approx.)
Sump TankCapacity 50 Ltrs.
Stop WatchElectronic
Pressure measurementBy differential pressure manometer

The present set-up is designed to study to find out the coefficientof permeability of a given medium. The setupconsists of a stainless steel pipe, which is filled withporous medium. Pressure tapings are provided on pipe tomeasure the pressure losses. A differential pressuremanometer is provided to measure the pressuredifference.Present set-up is self-contained water re-circulating unit,provided with a sump tank, centrifugal pump etc. Wateris pumped by means of centrifugal pump and passingthrough the pipe section, it returns back to the sumpwhich make the system re-circulating type. Flow of wateris diverted either to measuring tank or sump tank withthe means of a flow diverter, when needed. Flow controlvalve and by-pass valve are fitted in water line to conductthe experiment on different flow rates. Flow rate of wateris measured with the help of measuring tank withpiezometer and stopwatch. The supplied set-up iscomplete in all respect. Only water supply and electricitysupply is to be provided by the end user for running theset-up.
Yes! I am Interested
Get CALLBACK

Study of Pressure Measurement

Study of Pressure Measurement
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-124
Single Well ManometerSingle Tube Type
Differential ManometerU Tube Type.
Sensitive ManometerInclined Tube Type
Pressure GaugeBourdon Type
Water Circulation1/2 HP Pump,Crompton/Standard make
Sump TankCapacity 50 Ltrs.

The present set-up consists of different types of pressuremeasurement devices. These devices are pressurizedfrom pressure tapings, mounted on a water pipe line, inwhich water is pumped by means of a centrifugal pump.This pipe lines contains an orifice meter, pressure gaugeand control valve. Any one of the pressure measuringdevice can be selected to put under operation at a time.Present set-up is self-contained water re-circulating unit,provided with a sump tank, centrifugal pump etc. Wateris pumped by means of centrifugal pump and passingthrough the pipe section, it returns back to the sumpwhich make the system re-circulating type. Flow controlvalve and by-pass valve are fitted in water line to conductthe experiment on different flow rates. The supplied setupis complete in all respect. Only water supply,electricity supply and manometric fluid is to be providedby the end user for running the set-up.
Yes! I am Interested
Get CALLBACK

Bend Meter Test Rig

Bend Meter Test Rig
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-125
Bend meterMaterial Stainless steel Compatible to 1 inch Dia. Pipe.
Water Circulation1/2 HP Pump, Crompton/Standard make
Flow MeasurementUsing Measuring Tank with piezometer Capacity 25 Ltrs.
Sump TankCapacity 50 Ltrs. (approx.)
Stop WatchElectronic
Pressure measurementBy Pressurized differential pressure manometer

The present set-up is designed to study a bend meter andto calculate fluid discharge through it. By determining theco-efficient of discharge of this bend meter it can be usedas a flow meter and can be installed in a fluid line. Theapparatus consists of a pipe line in which a bend meter isinstalled. The pressure tapings from the bend meter istaken to differential pressure manometer to measurepressure difference.Present set-up is self-contained water re-circulating unit,provided with a sump tank, centrifugal pump etc. Wateris pumped by means of centrifugal pump and passingthrough the test section, it returns back to the sumpwhich make the system re-circulating type. Flow of wateris diverted either to measuring tank or sump tank withthe means of a flow diverter, when needed. Flow controlvalve and by-pass valve are fitted in water line to conductthe experiment on different flow rates. Flow rate of wateris measured with the help of measuring tank withpiezometer and stopwatch. The supplied set-up iscomplete in all respect. Only water supply and electricitysupply is to be provided by the end user for running theset-up.
Yes! I am Interested
Get CALLBACK

Fluid Properties & Hydrostatic Bench

Fluid Properties & Hydrostatic Bench
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-126
Universal HydrometerRange 0.70 to 2.00 sub-divided in 0.01 intervals
Falling Sphere Viscometer40mm tube diameter
Hydrostatic Pressure ApparatusComprises counter-balanced precision quadrant, pivoted on knife edges at its centre of arc.
Free Surface Tubes3 Different types.
Pressure GaugeBourdon Type.
ManometerDifferential Pressure Manometer, U Tube Type

The present set-up "Properties of Fluids and HydrostaticsBench" is designed to demonstrate the properties offluids and their beheaviour under hydrostatic conditionsi.e. when fluid is at rest. This allows students to developan understanding and knowledge of a wide range offundamental principles and techniques of fluid at rest,before studying fluids in motion. A variety of measuringdevices is incorporated, either fastened to the back of thebench or free standing. Water is stored in a stainless steeltank situated at the base of the unit. The water can betransferred by means of a FHP pump, to an elevated openstorage tank. This elevated tank has an overflow to avoidspillage. This elvated tank is connected to a number ofglass tubes for free surface studies. The various constanthead conditions can be achieved in this elevated tank.The set-up also consists of a pressure gauge andpressurized differential U tube manometer, mounted onthe panel. Hydrometer with hydrometer jar, fallingsphere viscometer jar, and capillary is also supplied withthe apparatus.
Yes! I am Interested
Get CALLBACK

Fluid Friction Measurement Apparatus

Fluid Friction Measurement Apparatus
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-142
Pipes 5 Numbers4 Smooth bore pipe and roughened bore pipe Diameters 1 19 x 16 mm Diameters 2 12.7 x 9.5 mm Diam
Distance between Taping1 m
FittingsStrainer, 90 degree Elbow, 45 degree Elbow, 45 degree Y, 90 T, Sudden Enlargement and Contraction
ValvesGate Valve, Ball Valve, Globe Valve.
Flow MetersVenturimeter, Orifice Meter Pitot Tube.
ManometerFor measuring pressure difference. 1 Manometer Tube Range 1000 mm of WC. 1 Manometer Tube Range 1000

The present set-up is designed to study the friction headlosses through pipes, fittings, and flow metering devices.Four different ID sizes smooth pipes and one artificiallyroughened pipe is connected in parallel. A valvearrangement is provided to operate the one pipe at atime. Various types of fitting are also fitted with pressuretaps to conduct the experiment. Venturi meter, orificemeter and pitot tube also accompanies the set-up. Tomeasure the pressure difference across the each fitting,pressure taps are taken to manometer with help of nonspillquick release couplings. Present set-up is selfcontainedwater re-circulating unit, provided with a sumptank, centrifugal pump etc. Water is pumped by means ofcentrifugal pump and passing through the selected testsections, it returns back to the sump which make thesystem re-circulating type. Flow of water is divertedeither to measuring tank or sump tank with the means ofa flow diverter, when needed. Flow control valve and bypassvalve are fitted in water line to conduct theexperiment on different flow rates. Flow rate of water ismeasured with the help of measuring tank withpiezometer and stopwatch. The supplied set-up iscomplete in all respect. Only water supply and electricitysupply is to be provided by the end user for running theset-up.
Yes! I am Interested
Get CALLBACK

Hydraulic Bench

Hydraulic Bench
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-151
Top TraySize 1000 x 700 x 100 mm (appro
Water Circulation1 HP Pump, Crompton/Standard make
Flow MeasurementUsing Measuring Tank with piezometer Capacity 40 Ltrs.
Sump TankCapacity 100 Ltrs.
Stop WatchElectronic
Pressure measurementBy Differential pressure manometer

The present set-up is designed to provide a platform andcontrolled water supply with flow measuring facility tothe different accessories in fluid mechanic. It is providedwith a top tray, sump tank, measuring tank and controlvalve. Various hydraulics experiments can be conductedon this set-up. A centrifugal Pump is fitted for watercirculation. A quick release coupling is provided in flexiblewater line to attach or detach any accessory to hydraulicbench with ease. Flow rate of water is measured with thehelp of measuring tank with piezometer and stop watch.Water collected on the top tray from experimental setup,drains and return to sump tank. A pressurizeddifferential pressure manometer also accompanies theset-up.Present set-up is self-contained water re-circulating unit,provided with a sump tank, measuring tank, centrifugalpump etc. Water is pumped by means of centrifugalpump and passing through the accessory under test, itreturns back to the sump which make the system recirculatingtype. Flow of water is diverted either tomeasuring tank or to sump tank with the means of a flowdiverter, when needed. Flow control valve and by-passvalve are fitted in water line to conduct the experimenton different flow rates. Flow rate of water is measuredwith the help of measuring tank with piezometer andstopwatch. The supplied set-up is complete in all respect.Only water supply and electricity supply is to be providedby the end user for running the set-up.
Yes! I am Interested
Get CALLBACK

Losses Due to Pipe Fittings, Sudden Enlargement & Contraction (Hydraulic Bench Accessory)

Losses Due to Pipe Fittings, Sudden Enlargement & Contraction (Hydraulic Bench Accessory)
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-152F
Sudden EnlargementFrom 15mm to 25mm
Sudden ContractionFrom 25mm to 15mm
Bend1/2 inch
Elbow1/2 inch
Ball Valve1/2 inch
Gate Valve1/2 inch

The present set-up is designed to study the pressurelosses due to pipe fitting installed in a pipe lines whichcauses major losses in pressure when a fluid flowsthrough these. The set up consists of a bend and elbow, asudden expansion & sudden contraction fitting, ball valveand gate valve. Pressure tapings are provided at inlet andoutlet of these fittingsPresent set-up is an accessory of Hydraulic Bench whichcan be connected to the Hydraulic Bench with providedquick release coupling. To operate this accessory end usershould have Hydraulic Bench which is provided withcontrolled water supply, flow rate measurement anddifferential pressure measurement facility.
Yes! I am Interested
Get CALLBACK

Reynold,s Apparatus (Hydraulic Bench Accessory)

Reynold,s Apparatus (Hydraulic Bench Accessory)
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-152H
Test Tube MaterialBorosillicate Glass
Test Tube ID10 mm (approx.)
Test Tube Length700 mm (approx.)
Dye ReservoirMaterial Stainless Steel
Dye Reservoir Capacity0.45 ltr. (approx.)

Present set-up is designed to observe the laminar,transitional and turbulent flow zones of fluid and to findthe Reynold’s Number. The apparatus consists of a glasstube mounted vertically and connected to a constanthead water tank. At the other end, a valve is provided tovary the flow rate of fluid flowing through this glass tube.Glass tube has a bell mouth entrance where a capillarytube is introduced in centre of the tube for feeding dyefrom a small container placed at the top of tank. Byvarying the rate of flow of water, the Reynolds’s numberis changed. This also changes the type of flow. Visualobservation of dye (Thread) will indicate the type of flow,which can be confirmed from the Reynolds numbercomputed.Controlled water supply with flow measuringarrangement, for the set-up, is to be provided by the enduser. Otherwise to operate this accessory, end usershould have Hydraulic Bench, which will providecontrolled water supply and flow rate measurementfacility.
Yes! I am Interested
Get CALLBACK

Metacentric Height Apparatus (Hydraulic Bench Accessory)

Metacentric Height Apparatus (Hydraulic Bench Accessory)
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-152J
PontoonMaterial Acrylic
pANprovided with Horizontal Guide Bar for sliding Weight Removable Strips Pointer with Scale Moveable h
Front Window of TankMade of Glass/Perspex.
A Set of Weightssupplied with the apparatus
Tanksmade of Stainless Steel

The present set-up is designed to study the metacentricheight of a ship model. The set-up consists of aRectangular tank for water, whose one side istransparent. A pontoon, made of acrylic, is allowed tofloat in this tank. The pontoon position on the water isvisualized through the transparent side.Supplied removable steel strips are placed in the shipmodel for the purpose of changing the weight of themodel. Displacement of weight is measured with the helpof a scale. By means of a pendulum (consisting of aweight suspended to a long pointer) the angle of tilt canbe measured. For tilting the ship model, a cross bar withmovable hanger is fixed on the model. A set of weights issupplied with the apparatus.
Yes! I am Interested
Get CALLBACK

Flow Meter Demonstration (Hydraulic Bench Accessory)

Flow Meter Demonstration (Hydraulic Bench Accessory)
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-152Q
Venturimeter MaterialAcrylic
Throat Dia14mm
Upstream Pipe Dia28mm
Orificemeter Plate MaterialStainless Steel
Throat Dia14 mm14 mm
Manometer Range0-500 mm
Tubes8 Nos.
Variable Area meter(2 - 20) LPM

Present set-up is an accessory of Hydraulic Bench. Theequipment consists of a Venturimeter, variable areameter and orifice plate installed in series, which permitsthe direct comparison of one with another. A controlvalve is fitted at the discharge end of the circuit to varythe flow through these flow meters. Pressure tapings atappropriate positions are provided to measure the headloss for each flow meter and are connected tomanometer to conduct the experiment. In this way thehead loss characteristics of each flow meter can beobserved and measured.The system is supplied with quick and easy couplingarrangement to connect with Hydraulic Bench.Manometer is pressurized with the help of a hand pumpfor observing the readings. The flow meters andmanometer are attached to a supporting back plate andframe which may be placed upon the top tray of thehydraulic bench.Present set-up is an accessory of Hydraulic Bench whichcan be connected to the Hydraulic Bench with providedquick release coupling. To operate this accessory end usershould have Hydraulic Bench which is provided withcontrolled water supply and flow rate measurementfacility.
Yes! I am Interested
Get CALLBACK

Orifice & Jet Velocity Apparatus (Hydraulic Bench Accessory)

Orifice & Jet Velocity Apparatus (Hydraulic Bench Accessory)
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-152U
Capacity14 Ltrs.
Cylinder MaterialClear Acrylic
Diameter200 mm
Height450 mm
Orifice2 Numbers
1 Diameter4 mm
2 Diameter8 mm

The present unit is an accessory of hydraulic bench. Theunit comprises a cylindrical clear acrylic tank. This tank isprovided with overflow and scale for observing the heightof the water, inside. Orifice of different diameter can befitted to the base of the cylinder. The path of the waterjet, leaving the tank, can be measured using trajectoryprobes which are adjusted by means of command screws.Each trajectory probe has a scale by which travelling ofprobe is noted and recorded to plot graph of water jet.Present set-up is an accessory of Hydraulic Bench whichcan be connected to the Hydraulic Bench with providedquick release coupling. To operate this accessory end usershould have Hydraulic Bench which is provided withcontrolled water supply and flow rate measurementfacility.
Yes! I am Interested
Get CALLBACK

Bernoulli's Theorem Apparatus (Hydraulic Bench Accessory)

Bernoulli's Theorem Apparatus (Hydraulic Bench Accessory)
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-152A
Test SectionMaterial Acrylic. Convergent and Divergent section
Piezometer TubesMaterial P.U. Nos. of Tubes 7 Nos.
Inlet TankCapacity 20 Ltrs. with fixed overflow arrangement.
TanksMade of Stainless Steel

The equipment is designed and fabricated todemonstrate the Bernoulli's theorem. It consists of a testsection made of acrylic. It has convergent and divergentsection. Pressure tapings are provided at differentlocations in convergent and divergent section. Pressurehead through these pressure tapping is taken to amanometer board and noticed.Present set-up is an accessory of Hydraulic Bench whichcan be connected to the Hydraulic Bench with providedquick release coupling. To operate this accessory end usershould have Hydraulic Bench which is provided withcontrolled water supply, flow rate measurement anddifferential pressure measurement facility.
Yes! I am Interested
Get CALLBACK

Impact of Jet on Vanes (Hydraulic Bench Accessory)

Impact of Jet on Vanes (Hydraulic Bench Accessory)
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-152D
TargetFlat Plate and Hemispherical Cup,1 No. each
NozzleMaterial Brass
Jet EnclosureMade of Acrylic
Counter weightsOne set of dead weights.

The setup consists of a clear Acrylic fabricated sectionfitted with a nozzle at the bottom. Water is fed throughthis nozzle and discharged vertically to strike a targetcarried on a stem, which extends through the cover. Aweight carrier is mounted on the upper end of the stem.The dead weight of the moving parts is counter balancedby a compression spring.The vertical force exerted on the target plate is measuredfor applied weights. Two targets are provided with thesetup, one is flat plate and other one is hemisphericalcup. Both targets can easily be attached and detached onthe stem, moving in transparent tank, without need ofany extra tool.Present set-up is an accessory of Hydraulic Bench whichcan be connected to the Hydraulic Bench with providedquick release coupling. To operate this accessory end usershould have Hydraulic Bench which is provided withcontrolled water supply and flow rate measurementfacility.
Yes! I am Interested
Get CALLBACK

Orifice Discharge (Hydraulic Bench Accessory)

Orifice Discharge (Hydraulic Bench Accessory)
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-152P
TankCylindrical, Clear Acrylic tank with orifice fitted in base.
OrificeSharp edged
Diameter15 mm
Transverse MechanismLead screw with adjusting nut calibrated 0.1mm per division

The Orifice Discharge set-up consists of a cylindrical tankwhich has an orifice fitted in the base. An X-Y assembly isprovide which enables a pitot tube to be positionedanywhere in the jet. Total five numbers ofinterchangeable orifices of same bore but differentprofile will be provided. The system also accompanies thepitot tube and knife edge to measure jet velocity anddiameter.Present set-up is an accessory of Hydraulic Bench whichcan be connected to the Hydraulic Bench with providedquick release coupling. To operate this accessory end usershould have Hydraulic Bench which is provided withcontrolled water supply and flow rate measurementfacility.
Yes! I am Interested
Get CALLBACK

Flow through Orifice & Mouthpiece

Flow through Orifice & Mouthpiece
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-102
Set of OrificesMaterial Acrylic Dia. 10mm and 15 mm 1 No. each
Set of MouthpiecesMaterial Acrylic (1 No. each of ) Dia. 10 mm (L/D = 1) Dia. 10 mm (L/D = 2.5) Dia. 10 mm (L/D = 4)
Pointer GaugeTo measure X-Y co-ordinates of Jet.
Water Circulation1/2 HP Pump,Crompton/Standard make.
Inlet tank35 Ltrs. provided with variable head arrangement.
Flow MeasurementUsing Measuring Tank with Piezometer,Capacity 25 Ltrs.
Sump Tank Capacity70 Ltrs.

The present set-up is designed to study the flow throughdifferent orifices and mouthpieces. It consists of an inlettank provided with diffuser and provision for fittingOrifice or Mouthpiece at the outlet which can be easilyattached or detached without need of any tool. Anoverflow arrangement is done to vary head and keep itconstant at desired level to conduct varieties ofexperiments. A pointer gauge for measuring X-Y coordinatesof Jet is fitted on flow channel.Centrifugal pump is used to re-circulate the water fromsump tank to the inlet tank and test section and is returnback to the sump tank. Flow diverter is provided to divertthe flow either to measuring tank or sump tank. Constanthead condition is maintained in the inlet tank.Experiments can be conducted on different flow ratesand measured with the help of measuring tank withpiezometer and stopwatch.
Yes! I am Interested
Get CALLBACK

Centre of Pressure Apparatus

Centre of Pressure Apparatus
 
Ask For Price
Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-118
Distance between suspended mass and fulcrum275mm
Cross sectional area of quadrant Torroid(100 x 100) mm2
Total depth of completely immersed quadrant160 mm
Height of fulcrum above quadrant100 mm

The Centre of Pressure Apparatus has been designed todetermine the static thrust exerted by a fluid on asubmerged surface and allow comparison of themeasured magnitude and position of this force withsimple theory.A fabricated quadrant is mounted on a balance arm,which pivots on knife-edges. The knife-edges coincidewith the centre of arc of the quadrant. Thus, of thehydrostatic forces acting on the quadrant whenimmersed, only the force on the rectangular end facegives rise to a moment about the knife-edges. Thebalance arm incorporates a balance pan for the weightssupplied and an adjustable counterbalancing deadweight. This assembly is mounted on top of an acrylictank, which may be leveled by adjusting screwed feet. Anindicator attached to the side of the tank shows when thebalance arm is horizontal. Water is admitted to the top ofthe tank by a flexible tube and may be drained through adrain cock in the side of the tank. The water level isindicated on a scale on the side of the quadrant.
Yes! I am Interested
Get CALLBACK

Electrical Analogy Apparatus

Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-119
Base PlateMaterial Ac
Water Tank75 mm depth (approx.) with convergent and divergent section
ProbeMade of copper/brass
Copper PlatesFixed on opposite side of the tank
Control PanelVariable DC Volt supplier and indicator

The present set-up consists of a base plate with base feet.A water tank is fixed on this plate. this water tank isdesigned so that it can be used as convergent ordivergent section. This tank is fabricated from acrylic. Theboth opposite sides of convergent to divergent or viceversa are fixed with copper plates through which a smallrange of DC electric volt is passed. A control panel withindicator is provided to supply DC Volts and read thesame with the help of probe.The Probe is mounted on a trolley, which can traverse intwo planes. By moving this probe in water tank the equipotentiallines can be located. X – Y Co-ordinates of theprobe at each point can be located on the scale fitted onthe cross slide. By supplying volts from divergent toconvergent and from convergent to convergent,observation are taken and recorded. After plotting thereading on a simple graph paper, the flow net can clearlybe studied.
 
Ask For Price
Yes! I am Interested
Get CALLBACK

Flow Channel (Hydraulic Bench Accessory)

Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-152R
Flow Channel Width of Channel15 mm
Depth of Channel150 mm
Length of Channel600 mm
Water CirculationBy using Hydraulic Bench
Dye Injection Needles5 Nos.

This apparatus consists of a Open Flow channel with inletsection. The equipment is designed to study the variousphenomenon and patterns of flow with the help ofvarious types of models. The channel section istransparent by which user can observe the various flowpatterns of fluid in the channel and photographs can betaken. A dye injection system is also provided at the inletof the channel to visualize the flow pattern. At the inlet ofthe channel stilling and smoothening device is providedfor obtaining the excellent velocity profile in the testsection. At the discharge side a weir is provided whichhave an adjustable height. This weir maintains theoperating water level for the channel.Present set-up is an accessory of Hydraulic Bench whichcan be connected to the Hydraulic Bench with providedquick release coupling. To operate this accessory end usershould have Hydraulic Bench which is provided withcontrolled water supply and flow rate measurementfacility.
 
Ask For Price
Yes! I am Interested
Get CALLBACK

Cavitation Apparatus (Hydraulic Bench Accessory)

Product Price:  
Get Latest Price
Product Brochure

Product Details:
Model Name/NumberKCFM-152W
Test SectionMaterial Acrylic
Pressure Gauge0-4 kg/cm2
Vacuum Gauge0-760 mmHg

The apparatus has been designed to demonstrate thephenomenon of cavitations. The present set-up consistsof a test section made of Acrylic having conversion anddiversion section. Pressure tapings at appropriateposition are provided. This test section is having onecontrol valve at upstream side to regulate the water flowrate. Two pressure gauges are connected to these tapingwhich give the pressure readout at the time of flowpassing through this test section.Present set-up is an accessory of Hydraulic Bench whichcan be connected to the Hydraulic Bench with providedquick release coupling. To operate this accessory end usershould have Hydraulic Bench which is provided withcontrolled water supply and flow rate measurementfacility.
 
Ask For Price
Yes! I am Interested